Turbidity measuring for lab to fermenter production
The turbidity measurement system is used in the chemical, pharmaceutical, biotechnology, food and petrochemical industries. The in-situ sensor measures on one level based on the reflection principle.
turbymex - the turbidity meter The system measures the crystallisation and cell density increase or monitors the filtration process or condensate
The ATM100 allows a 6-point linearisation per channel. Up to four measuring points can be operated via the bus. From sensors in 316L stainless steel with a fibre optic cable and remote local coupler electronics to mounted versions in various nominal sizes, almost anything is possible. The sum signal is high-resolution and sensitive due to the optical receiver lens.
Turbidity measurement
Why customers rely on aquasant® turbidity measuring technologyTyp: ATM100
- In-situ real-time measurement
- Long-term stability due to controlled light source
- Use in sterile areas
- CIP (cleaning in place) and SIP (sterilisation in place) up to 230°C
- High reproducibility
- Sensors for different solids concentrations
- Customer-specific sensor designs
- Ex design according to ATEX / FDA compliant
- Datalogger with export function
- Ethernet interface
- The fundamental technology has proven itself since the 1980s
Measuring system
- Turbidity meter ATM100
- Coupler ATA100
- Turbidity sensor AF44/43
- New AF44 I Gv ATA*
- Calibration vessel AF44 EG
The evaluation electronics not only serve as a feed unit to the 4-wire bus, but also house the data processing intelligence in a secure manner with dynamic monitoring. All four measuring inputs have the same functionality.
The benefit for you: high economic efficiency and investment security due to the long service life.
Each of them has an analog output of 4 - 20 mA with galvanic isolation
Each of them has 2 limit value relay outputs
1 to 4 measuring inputs via the bus for ATA100 sensor connection
6 linearisation points
Data logger with Excel export function
Ethernet web application
Ex version: Gas II (2) G [Ex ia Gb] IIC EMC STS 024 CE ****
Ex version: Gas II (2) G [Ex ia Gb] IIC EMC STS 024 CE ****
The coupler serves as the actual IR measurement and transmission unit from the ATM feed unit to the 4-wire bus. Variations available: remote version or mounted on sensor.
The benefit for you: long-term stability is guaranteed through the controlled light source.
RS485 bus A/B
IR-LED 880 nm stabilised, fibre optic cable connection coupler
Up to 3 further couplers via the bus for ATA100 sensor connection
Housing in powder-coated aluminium or stainless steel
Ex design: Gas EEx II 1/2G EEx emb II T6 EMC STS 024 CE ****
The benefit for you: long-term stability is guaranteed through the controlled light source.
Ex design: Gas EEx II 1/2G EEx emb II T6 EMC STS 024 CE ****
The standardised probes are produced according to process conditions and the media to be used in a customer-specific way. The AF44 sensor with a flat probe window is used for turbidity levels up to 60 g/l, while the AF43 with a conical window is used for >200 g/l of dry yeast.
Materialisation: Stainless steel, Hastelloy®, PP designs
Sensor shaft lengths, position of O-ring groove standardised or customer-specific
Process connection Ø 25 mm with G11/4" union nut or GL Ø 19/14/12 mm
Versions available: with mounted coupler or in fibre optic cable
Ex version: EEx II 1/2G EEx emb II T6
Ex version: EEx II 1/2G EEx emb II T6
The AF44 fibre optic sensors are NEW and available with compact and mounted ATA100 coupler electronics in stainless aluminium or steel housing.
Mounted connection head with ATA100* and/or with cooling element, product temperatures up to 120°C
Materialisation: Stainless steel, Hastelloy®, PP design
Sensor shaft lengths, position of O-ring groove standardised or customer-specific
Process connection Ø 25 mm with G11/4" union nut
Connection head for aluminium powder-coated IP65 or stainless steel P68
The calibration vessel is equipped with a cleaning device (wiper against bubble formation). Material: POM; not sterilisable; volume: 100 ml.
Incl. 3 adapters for bar probes AF44 CS/R 19 mm / AF 44 I S/R 25 mm
AF43 S/R 25 mm (without wiper)
2 magnetic stirrers, smooth, 6 x 20 mm with PTFE coating and black anti-reflective protection
Documentation
Monitoring of cell density in the fermenter
The turbidity measurement system developed for the biotechnology industry is primarily used for the online measurement of cell density in bioreactors and fermenters. As a function of cell density, the turbidity signal is indispensable as an additional control parameter for research, development and production.
Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs:Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF44 I SR ø12mm with fiber optic cable
Tech Docs: Turbidity sensor type AF44 I SR ø12mm PG13.5 with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
PDF download
Brochure: Turbidity meter type: ATM100Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs:Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF44 I SR ø12mm with fiber optic cable
Tech Docs: Turbidity sensor type AF44 I SR ø12mm PG13.5 with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
Condensate monitoring
By measuring the turbidity, the safeguarding of the cooling circuit in industrial applications is guaranteed. Due to the high resolution of the measurement signal, it is possible to measure the oil concentration in the condensate or cooling water in the ppm range following the deployment of a heat exchanger.
Tech Docs: Turbidity sensor type AF44 I G K ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM1
PDF download
Brochure: Turbidity meter type: ATM1Tech Docs: Turbidity sensor type AF44 I G K ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM1
Crystallisation monitoring
Our measuring system meets the high industrial requirements through to the Ex zone. The turbidity meter monitors the crystallisation process in pipelines or directly in reactors.
Tech Docs: Turbidity sensor type AF44 I G K ATA
Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
PDF download
Brochure: Turbidity meter type: ATM100Tech Docs: Turbidity sensor type AF44 I G K ATA
Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
Filtration monitoring
Our measuring system meets the high industrial requirements through to the Ex zone. The turbidity meter monitors the filtration process with the highly sensitive AF44* sensors down to the ppm range.
Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
PDF download
Brochure: Turbidity meter type: ATM100Tech Docs: Turbidity sensor type AF44 I Gv ATA
Tech Docs: Turbidity sensor type AF44 I SR with fiber optic cable
Tech Docs: Turbidity sensor type AF43 I SR with fiber optic cable
Tech Docs: Turbidity meter type: ATM100
New: Firmware update V1.38a ATM100
The benefits you receive from the update of the turbidity meter ATM 100 V1.21 or older versions
The MS Excel 2016 add-in for processing exported ATM100 data files is new: the zip file is available for download.