{"id":1529,"date":"2017-09-05T11:36:18","date_gmt":"2017-09-05T09:36:18","guid":{"rendered":"http:\/\/www.aquasant-mt.com\/portfolio-item\/grenzwert\/"},"modified":"2023-11-14T15:56:14","modified_gmt":"2023-11-14T14:56:14","slug":"mls1100-limit-value-switch-dynamic-foam-detection-dead-space-free-probes-for-reactors-fermenter-in-biotec","status":"publish","type":"portfolio","link":"https:\/\/www.aquasant.com\/en\/portfolio-item\/mls1100-limit-value-switch-dynamic-foam-detection-dead-space-free-probes-for-reactors-fermenter-in-biotec\/","title":{"rendered":"Limit Switch detection (Foam)"},"content":{"rendered":"<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2018\/03\/Header_Anwendungen_Grenzwert_EN.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>Heading + desc<\/p>\n<h4>\nThe limit value switch monitors the dynamic and\/or static limit value for foam. Universally usable, allows for reliable detection, combined with easy commissioning. A reliable measurement of all products is guaranteed by applying the impedance measuring principle.<\/h4>\n<h5>mipromex\u00ae  \u2013 the limit value switch<br \/>\nThe evaluation unit monitors, detects and controls the addition of the defoamer<\/h5>\n<p>The guaranteed foam detection of products with varying consistencies, electrical and dielelectrical conductivity is achieved by the dynamic three-dimensional measurement behaviour. The limit value output controls the cost-conscious use of the foam precipitating agent closes the pressure valve or interrupts the vacuum, etc.<\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>0 15% 0 0<\/p>\n<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/07\/aquasant_Home_03_slim_dreieck.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>Aquasant limit switch foam detection in sterile zone<\/p>\n<p>Heading + desc<\/p>\n<h5>Foam monitoring<\/h5>\n<p><b>Why customers rely on aquasant\u00ae foam detection<\/b><\/p>\n<h6>\n<ul>\n<li>Detection of a wide range of foam types<\/li>\n<li>Measurement without sensitivity to contamination<\/li>\n<li>Differentiation between foam and fluid through two measurement areas in a serial \u201csingle rod\u201d design<\/li>\n<li>Probes in extremely small designs for labs and pilot plants (in rotating evaporators, lab fermenters, single-use bioprocess bags)<\/li>\n<li>Dead space-free probes<\/li>\n<li>Resistant for CIP, SIP<\/li>\n<li>Foam detection in non-conductive tubes when filling with sterile material<\/li>\n<li>Curved probes for special installation<\/li>\n<\/ul>\n<\/h6>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>30px<\/p>\n<p>Measuring system<\/p>\n<h5>mipromex\u00ae MLS<\/h5>\n<p>: The<br \/>\n<em><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/grenzwertschalter-mls1100\/\"> MLS<\/a> <\/em> tlimit value switch can be used for foam detection, fluids or powder level measuring. The first and second measurement circuits are equipped with the same functionality. The evaluation electronics not only serves as a feed unit in the 2-wire technology, it also houses the data processing intelligence.<\/p>\n<p>Your benefit: High economic efficiency and investment security due to the long service life.<\/p>\n<ul>\n<li> Limit value on the active measurement range length can be freely parameterised<\/li>\n<li>  Easy fault visualisation, fault notifications on 2nd relay output, if selected<\/li>\n<li> With 1 or 2 measuring inputs<\/li>\n<li> Limit value simulation<\/li>\n<\/ul>\n<p><b>Ex version:<\/b> Gas II (2) G [Ex ia Gb] IIC SEV 09 ATEX 0132; EMC  STS 024 CE 1254<\/p>\n<p><em><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/grenzwertschalter-mls1100\/\">Further information on MLS\u00bb<\/a> <\/em><\/p>\n<h5>Bar probe<\/h5>\n<p>: The standardised bar probe is configured to customer-specific process conditions and the media used.<\/p>\n<ul>\n<li>Materialisation: Stainless steel, Hastelloy\u00ae, full PTFE designs<\/li>\n<li>Process connection: Flange DN, ANSI or threading<\/li>\n<li>For insulated lines with extension for detached connection head and\/or with a cooling element for product temperatures of up to 170\u00b0 C<\/li>\n<li>Connection head for indoor IP65 or outdoor IP68 in Exd<\/li>\n<\/ul>\n<h5>Specific bar probe<\/h5>\n<p>: The standardised bar probes are configured to customer-specific process conditions and the media used. The probe technology, in contrast to the capacitive system, is also suitable for insulating, low-polarity foams.<\/p>\n<ul>\n<li>Materialisation: Stainless steel, Hastelloy\u00ae, full PTFE designs<\/li>\n<li>Contamination in the inactive area and organic residues on the measuring electrode are negligible<\/li>\n<li>Designs for extreme process conditions with temperatures of up to max. 300\u00b0C and pressure up to 1000 bar<\/li>\n<li>The quick measurement, 300 ms, guarantees reliable detection<\/li>\n<\/ul>\n<p>horizontal<\/p>\n<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/09\/LKW-Abf\u00fcllstation2.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>Aquasant-Grenzwert-Auswerteger\u00e4t Typ MLS1*<\/p>\n<p>foam detection bar probe at truck filling<\/p>\n<h5>Documentation<\/h5>\n<p>: Limit value probes for organic and aqueous foams<\/p>\n<p>Our impedance measuring principle and the high-resolution MTI measuring electronics can record all types of foam both analogue, as a fill level tendency or digitally, as a limit value. A wide range of probes allows for all types of installation. The spatial measurement behaviour of the foam probes makes it easy to detect foams. Thanks to the product-specific probe, combined with the dynamic limit value detection, various types of foams can even be determined if the probe is contaminated. The mipromex\u00ae MLS evaluation unit is equipped with a graphic display for visualising the foam level and setting the limit value.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-638\" src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/09\/ATEX_logo-EX-300x260.png\" alt=\"\" width=\"40\" height=\"30\"><\/p>\n<hr>\n<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/09\/acrobat-con.png\"><\/p>\n<h6>PDF download<\/h6>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/VDP-Applikation-Grenzwert-Schaumdetektion-Bio.pdf\" target=\"blank\" rel=\"noopener\"><b>Brochure:<\/b> Foam detection<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/VDD-Stabsonde_STL-SB-T-GS-A-TC1-FD-TF-ST.pdf\" target=\"blank\" rel=\"noopener\"><b>Tech Docs:<\/b> Limit switch bar probe type STL TC1<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/VDD-Stabsonde_STMv-380-300-SB-RT-GS-A-K-KU3-FD-TF-ST.pdf\" target=\"blank\" rel=\"noopener\"><b>Tech Docs:<\/b> Limit switch bar probe type STMv KU3<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/11\/VDP-mipromex_MLS.pdf\" target=\"blank\" rel=\"noopener\"><b>Tech Docs:<\/b> Limit Switch-unit type MLS<\/a><\/p>\n<p>accordion<\/p>\n<p>grenzwert-schaum<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Betriebsorte<\/p>\n<h4>Geeignet f\u00fcr folgende Betriebsorte:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Labor<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Miniplant<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Pilotplant<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Produktion<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Lagerung<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Abf\u00fcllung<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Sparten<\/p>\n<h4>Geeignet f\u00fcr folgende Sparten:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/impedanzmessung\" class=\"aquabutton\"><b>Impedanzmessung<\/b> <\/a><br \/>\n<a href=\"https:\/\/www.aquasant.com\/portfolio-item\/impulsradar\" class=\"aquabuttonpassive\"><b>Impulsradar<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/elektrooptisch\" class=\"aquabuttonpassive\"><b>Elektrooptisch<\/b> <\/a><br \/>\n<a href=\"https:\/\/www.aquasant.com\/portfolio-item\/leitwert\" class=\"aquabuttonpassive\"><b>Leitwert<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/ultraschall\" class=\"aquabuttonpassive\"><b>Ultraschall<\/b> <\/a><br \/>\n<a href=\"https:\/\/www.aquasant.com\/portfolio-item\/glas\" class=\"aquabuttonpassive\"><b>Glas<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/portfolio-item\/ventil\" class=\"aquabuttonpassive\"><b>Ventil<\/b> <\/a><br \/>\n<a href=\"https:\/\/www.aquasant.com\/portfolio-item\/gehaeuse-el-geraete\" class=\"aquabutton\"><b>Geh\u00e4use el. Ger\u00e4te<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Branchen<\/p>\n<h4>Suitable for the following industries:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>chemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>petrochemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>biochemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>biodiesel<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>biotechnology<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>pharmaceutical<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>surfactants<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>laquers &amp; paint<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>animal feed<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>cosmetics<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>plant engineering<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>planning &amp; engineering services<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>energy &amp; environment<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>R &amp; D<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>plastics technology<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>services providers<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>paper &amp; forestry products<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>construction material<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>distributors<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>petroleum tank farms<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>private households<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonpassive\"><b>wholesalers<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>tank inspectors<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>petrol stations<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>surge tanks<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>communities<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Der Grenzwertschalter \u00fcberwacht den statischen und\/oder dynamischen Grenzwert f\u00fcr Schaum und Fl\u00fcssigkeiten. Universell einsetzbar, f\u00fcr sichere Detektion  und einfache Inbetriebnahme. Eine zuverl\u00e4ssige Messung aller Produkte wird durch das Impedanzmessprinzip garantiert.<\/p>\n<h5>mipromex\u00ae  \u2013 der Grenzwertschalter<br \/>MLS 1* Niveau-Auswerteger\u00e4t<br \/>\u00dcberwacht, detektiert und regelt die Antischaumzufuhr<\/h5>\n","protected":false},"author":8,"featured_media":444,"menu_order":8,"comment_status":"open","ping_status":"closed","template":"","meta":[],"portfolio-types":[91],"_links":{"self":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio\/1529"}],"collection":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/comments?post=1529"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/media\/444"}],"wp:attachment":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/media?parent=1529"}],"wp:term":[{"taxonomy":"portfolio-types","embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio-types?post=1529"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}