{"id":1417,"date":"2018-01-15T17:05:28","date_gmt":"2018-01-15T16:05:28","guid":{"rendered":"http:\/\/www.aquasant-mt.com\/?post_type=portfolio&#038;p=1417"},"modified":"2023-11-14T15:32:11","modified_gmt":"2023-11-14T14:32:11","slug":"mil-miq8130-liquid-phases-detection-interfacial-layer-continous-measurement-in-decanters","status":"publish","type":"portfolio","link":"https:\/\/www.aquasant.com\/en\/portfolio-item\/mil-miq8130-liquid-phases-detection-interfacial-layer-continous-measurement-in-decanters\/","title":{"rendered":"Interface measurement <b>continuous<\/b> phase detection"},"content":{"rendered":"<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/11\/Header_Anwendungen_Trennschicht_EN.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>Heading + desc<\/p>\n<h1>Continuous separation layer measurement in the decanter<\/h1>\n<h2>Separation layer measurement of non-mixable fluids with emulsion, phase reverse, as generated during extraction or after a chemical process, is our strength. We control the phase level with the impedance measurement despite severe contamination, extremely small density differences or layers of mulch.<\/h2>\n<h5>mipromex \u2013 the multi-talent<br \/>\nThe separation layer unit monitors, detects and controls the separation layer<\/h5>\n<p>The high-resolution separation layer measurement system continuously monitors the separation layer in decanters, mixer-settlers and columns or in pipelines. Our customers are impressed by the universal use, high measurement precision and easy commissioning. A reliable measurement of all products is guaranteed by applying the impedance measuring principle. The self-monitoring measuring and control unit ensures reliable phase monitoring.<\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>0 15% 0 0<\/p>\n<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/07\/aquasant_Home_05_slim_dreieck.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>Aquasant Interface layer measurement system unit<\/p>\n<p>Heading + desc<\/p>\n<h5>Fluid\/fluid phase separation<\/h5>\n<p><b>Why customers rely on aquasant\u00ae separation layer measuring technology<\/b><\/p>\n<ul>\n<li>Sum measurement signal instead of runtime measurement<\/li>\n<li>Density independence<\/li>\n<li>Separation layer measurement of two organic phases<\/li>\n<li>Measurement through glass instruments without touching the product<\/li>\n<li>Measurement without sensitivity to contamination<\/li>\n<li>Serial design of two measurement ranges in \u201csingle rod\u201d<\/li>\n<li>Desalination systems under high voltage (50kV)<\/li>\n<li>Lab probes in extremely small designs<\/li>\n<li>Curved probes for special installation<\/li>\n<\/ul>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>30px<\/p>\n<h5>mipromex MIQ<\/h5>\n<p>: The multi-talented <em><a href=\"https:\/\/www.aquasant.com\/en\/portfolio-item\/interfacialunit-miq8130\/\"> MIQ<\/a><\/em> can be used from the separation layer level measurement to batch separation. With the option of a 2nd measurement circuit, the phase monitoring system, the fill level or the separation behaviour can be measured. The evaluation electronics not only serve as a feed unit in the 2-wire technology, it also houses the data processing intelligence.<br \/>\nYour benefit: High economic efficiency and investment security due to the long service life.<\/p>\n<ul>\n<li>Universally usable, reduced storage costs<\/li>\n<li>With one or two measuring inputs<\/li>\n<li>Continuous separation layer monitoring<\/li>\n<li>Phase monitoring for safety-optimised separation<\/li>\n<li>Combination with level measuring of the upper phase<\/li>\n<\/ul>\n<p><b>Ex version:<\/b> Gas II (2) G [Ex ia Gb] IIC \/ Dust II (2) D [Ex ia Db] IIIC<br \/>\n\/ Gas (2) D [Ex d ia] IIC<br \/>\nEMC STS 024 CE ****<\/p>\n<h5>mipromex MIL<\/h5>\n<p>: The soloist, <em><a href=\"https:\/\/www.aquasant.com\/en\/portfolio-item\/interfacialunit-mil8130\/\"> MIL<\/a><\/em>, focuses the functionality on continuous separation layer measuring. The evaluation electronics not only serve as a feed unit in the 2-wire technology, it also houses the data processing intelligence.<br \/>\nYour benefit: Maintenance-free and cost-effective due to long service life.<\/p>\n<ul>\n<li>Continuous separation layer monitoring<\/li>\n<li>With one measuring input<\/li>\n<li>Easy fault visualisation, fault notifications on analogue output<\/li>\n<li>mA output and limit value simulation<\/li>\n<\/ul>\n<p><b>Ex version:<\/b> Gas II (2) G [Ex ia Gb] IIC \/ Dust II (2) D [Ex ia Db] IIIC<br \/>\n\/ Gas (2) D [Ex d ia] IIC<br \/>\nEMC STS 024 CE ****<\/p>\n<h5>QTI 820<\/h5>\n<p>: The QTI 820 K measuring unit works according to the same principle as the mipromex separation layer measuring unit. The 2nd channel allows for a phase to be measured and compensated even if this phase\u2019s properties change. The evaluation electronics not only serve as a feed unit in the 2-wire technology, it also houses the data processing intelligence.<\/p>\n<ul>\n<li>Product compensation for variable phases<\/li>\n<li>QTI 820 K can only be used for continuous separation layer level measuring<\/li>\n<li>With two measuring inputs<\/li>\n<li>Fault visualisation, fault notifications on relay output<\/li>\n<\/ul>\n<h5>Continuous bar probe<\/h5>\n<p>: The standardised bar probes are configured to customer-specific process conditions and the media used and are maintenance-free. In contrast to the conventional measuring systems, the aquasant probe technology does not require any moving parts and is independent of dielectricity constant, density and organic residues.<\/p>\n<ul>\n<li>Materialisation in accordance with requirement (e.g. stainless steel, Hastelloy\u00ae, full PTFE designs)<\/li>\n<li>Organic contamination or residues are negligible<\/li>\n<li>Designs for extreme process conditions with temperatures of up to max. 300\u00b0C and pressure up to 1000 bar<\/li>\n<li>Reliable measurement even for the above aqueous phase (phase reversal)<\/li>\n<\/ul>\n<h5>Tube sensor (batch)<\/h5>\n<p>: With decades of experience in the field of phase separations, we face every challenge with the auto-dynamic batch separation.<\/p>\n<p>Our unique TSS80 tube probes are specifically configured in accordance with your process conditions. All ring probes are parameterised at the factory and do not require commissioning: simply plug&amp;process.<\/p>\n<p>horizontal<\/p>\n<p><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/mixersettler2.jpg\" alt=\"\"><\/p>\n<p>center<\/p>\n<p>75<\/p>\n<p>Aquasant Continuous separation layer measurement in the decanter Mixer Settler<\/p>\n<p>Trennschicht-Sonde im Mixer Settler<\/p>\n<h5>Documentation<\/h5>\n<p>: Continuous interface measurement with mipromex MIQ or MIL with bar probe STM according to customer specification<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-638\" src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/09\/ATEX_logo-EX-300x260.png\" alt=\"\" width=\"40\" height=\"30\"><\/p>\n<hr>\n<p><a href=\"https:\/\/www.aquasant.com\/downloads\" target=\"blank\" rel=\"noopener noreferrer\"><img src=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/09\/acrobat-con.png\"><\/a><\/p>\n<h6>PDF download<\/h6>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2019\/09\/VEP-Application-Interface-Level.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Brochure:<\/b> Interface level measurement<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2018\/06\/VED-Bar-probe_STM-1550-750-SB-R-TN-ES4-ANSI2-C-ExG.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface bar probe type STM (316L)<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2018\/06\/VED-Bar-probe_STMd-950-600-SB-R-TN-ES4-K-DN80-C2-ExG.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface bar probe type STMd (316L)<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2018\/06\/VED-Bar-probe_STM-1200-500-SB-T-TN-ANSI2-C-ExG.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface bar probe type (full-PTFE)<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2019\/09\/VED-Klammersonde_FRGL-SE-R-U-EF-GR60-V-ExG.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface clamp probe for Glass tube type FRGL80\/60 SE R U EF GR60<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2019\/09\/VEP-mipromex_MIQ-Techn-Dok.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech. Docs:<\/b> Interface evaluation unit mipromex type MIQ Multitalent<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2019\/09\/VEP-mipromex_MIL-Techn-Dok.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface evaluation unit mipromex type MIL Solist<\/a><\/p>\n<p><a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/VDD-Stabsonde_STM-710-400-40-SB-TL-T3-2TN-ES6-DN-C2-ExG.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface bar probe type STM 2TN<\/a><br \/>\n<a href=\"https:\/\/www.aquasant.com\/wp-content\/uploads\/2017\/10\/in-Bearbeitung.pdf\" target=\"blank\" rel=\"noopener noreferrer\"><b>Tech Docs:<\/b> Interface evaluation unit type QTI 820<\/a><\/p>\n<p>accordion<\/p>\n<p>trennschicht<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Sparten<\/p>\n<h4>Geeignet f\u00fcr folgende Sparten:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/impedanzmessung\"><b>Impedanzmessung<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/impulsradar\"><b>Impulsradar<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/elektrooptisch\"><b>Elektrooptisch<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/leitwert\"><b>Leitwert<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/ultraschall\"><b>Ultraschall<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/glas\"><b>Glas<\/b> &lt; no-repeat;center top;; auto <\/a><a class=\"aquabuttonpassive\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/ventil\"><b>Ventil<\/b> <\/a><br \/>\n<a class=\"aquabutton\" href=\"https:\/\/www.aquasant.com\/portfolio-item\/gehaeuse-el-geraete\"><b>Geh\u00e4use el. Ger\u00e4te<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Betriebsorte<\/p>\n<h4>Geeignet f\u00fcr folgende Betriebsorte:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Labor<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Miniplant<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Pilotplant<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Produktion<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabutton\"><b>Lagerung<\/b> <\/a><br \/>\n<a class=\"aquabutton\"><b>Abf\u00fcllung<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p>20<\/p>\n<p>default<\/p>\n<p>default<\/p>\n<p>Branchen<\/p>\n<h4>Suitable for the following industries:<\/h4>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>chemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>petrochemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>biochemistry<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>biodiesel<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>biotechnology<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>pharmaceuticals<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>surfactants<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>laquers &amp; paint<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>animal feed<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>cosmetics<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>plant engineering<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>planning &amp; engineering services<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>energy &amp; environment<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>R &amp; D<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>plastics technology<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>service providers<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonbranche\"><b>paper &amp; forestry products<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>construction materials<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>distributors<\/b> <\/a><br \/>\n<a class=\"aquabuttonbranche\"><b>petroleum tank farms<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>private households<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n<p><a class=\"aquabuttonpassive\"><b>wholesalers<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>tank inspectors<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>petrol stations<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>surge tanks<\/b> <\/a><br \/>\n<a class=\"aquabuttonpassive\"><b>communities<\/b> <\/a><\/p>\n<p>no-repeat;center top;;<\/p>\n<p>auto<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Trennschichtmessung mit nicht mischbarer Fl\u00fcssigkeiten, Mulmschichten, Phasenumkehr oder leitf\u00e4higen organische Phasen kann sehr problematisch sein \u2013 seien sie bei einer Extraktion oder nach einem chemischen Prozess entstanden. Starke Verschmutzung, kleinste Dichteunterschiede oder auch Emulsionsschichten k\u00f6nnen dazu f\u00fchren, dass automatische Prozessabl\u00e4ufe durch eine zeitraubende Handabtrennung unterbrochen werden m\u00fcssen.<\/p>\n","protected":false},"author":8,"featured_media":450,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"portfolio-types":[91],"_links":{"self":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio\/1417"}],"collection":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio"}],"about":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/types\/portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/comments?post=1417"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/media\/450"}],"wp:attachment":[{"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/media?parent=1417"}],"wp:term":[{"taxonomy":"portfolio-types","embeddable":true,"href":"https:\/\/www.aquasant.com\/en\/wp-json\/wp\/v2\/portfolio-types?post=1417"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}