| Technical data | ||
| Supply voltage: | 24VAC 50 - 60 Hz / DC / -10%..50% | |
| Power consumption: | Approx. 9VA (AC) / 6 VA (DC) | |
| Emitted measurement signal: | 880nm | |
| Ambient temperature: | +5°C .. 45°C | |
| Analogue output: | 0..20mA or 4..20mA | |
| Relay breaking capacity | max. 250V, 1A, 100VA | |
| Measuring range: | >10E 10 cells per ml or >200g per liter Solid suspension (product dependent) Calibration required! | |
| Technical data | ||
| Ex-classification: | II 2G EEx emb II T4 (pre-amplifier) | |
| Supply voltage: | 24VAC/DC -20%..+25% | |
| Power consumption: | max. 15VA | |
| Number of measuring points: | up to max. 4 measuring points at the same time | |
| Ambient temperature: | 0C … 60C | |
| Analogue output: | 0…20mA or 4…20mA | |
| Relay breaking capacity: | 2 per measuring point max. 42 VAC, max. 0.5A, max. 50VA | |
| Measuring range: | 0 .. 10000NTU <+/- 2% linearized | |
| Display: | full graphic display 240x160 pixels monochrom | |
| Technical data | ||
| Supply voltage: | 24VAC/DC -20%..+25% | |
| Power consumption: | max. 15VA | |
| Number of measuring points: | 1 measuring point | |
| Ambient temperature: | 0C … 60C | |
| Analogue output: | 0…20mA or 4…20mA | |
| Relay breaking capacity: | Switch contact C, NC, NO | |
| Measuring range: | 0 .. 4000 NTU automatically selectable after calibration | |
| Display: | Alphanummerical display 2x16 digits | |